DIAPHRAGM
SEAL PROTECTORS
 |
Protective device used
to isolate the pressure instrument from the process fluid being monitored.
MODEL W - WELDED DIAPHRAGM SEALS
Contains metal diaphragm welded to the upper housing. Bolts can be removed and
separated at the flanges for cleaning, liquid filling, calibrating, welding, or
other purposes, without the loss of the liquid fill fluid. Available with
flushing connection. Threaded off-line, flanged off-line and flow through
styles are available in many configurations and materials.
|
MINI DIAPHRAGM SEAL PROTECTORS
Economical isolator designed to protect
instruments from corrosion and clogging.
MODEL
M -- MINI SEALS FOR UP TO 3 1/2" GAUGES
-
All-Welded, gasketless design
-
For pressure gauge dial sizes to
3-1/2"
-
1/4" or 1/2" NPT instrument
connection
-
1/4" or 1/2" NPT process
connection
-
Minimum pressure gauge range of
0-100 psi
-
Standard Pressure Rating: 2000
psi @ 100°F
-
Optional 5000 psi pressure
rating
-
1/8" or 1/4" NPT flushing
connection optional
-
Low volume rendition optional
-
Materials: 316SS, Monel,
Hastelloy B or C, & Carpenter 20
MODEL M -- MINI SEAL FOR UP
TO 4 1/2" GAUGES
-
All-Welded, gasketless design
-
For pressure gauge dial sizes to
4-1/2"
-
1/4" or 1/2" NPT instrument
connection
-
1/4", 1/2", 3/4", or 1" NPT
process connection
-
Minimum pressure gauge range of
0-15 psi
-
Standard Pressure Rating: 1000
psi @ 100°F
-
1/8" or 1/4" NPT flushing
connection optional
-
Materials: 316SS, Monel,
Hastelloy B or C, & Carpenter 20
|
Top
SANITARY
DIAPHRAGM SEAL PROTECTORS
Designed for food,
dairy, and pharmaceutical industries to ensure that surfaces exposed to process
are virtually crack and crevice free.
MODEL
S -- SANITARY SEALS
All-welded construction which
allows removal from system without loss of fill fluid. Construction conforms to
methods as described in ASME Standard B20.2-1991, Section 2.3.12. This off-line
seal has a diaphragm welded to the upper housing. It is designed to ensure that
the surfaces exposed to the process are virtually crack and crevice free. They
meet the requirement of the 3-A Sanitary Standard.
|
Top
DIAPHRAGM
SEAL ACCESSORIES
FILL FLUIDS
Fill fluids should be selected
by carefully considering their physical properties at the extremes of the
ambient and process temperature to which they will be subjected. Fill fluids
must also be chemically compatible with the process fluid to avoid potentially
hazardous reaction in the event of diaphragm failure. Typically, hydrocarbon
based liquids must not be used with strong oxidizers, such as oxygen, chlorine,
hydrogen peroxide, or nitric acid. For these special applications, an
inert liquid such as Fluorolube or Halocarbon is available. Fill fluids diluted
with or containing water will not be supplied by Tel-Tru Manufacturing. The
presence of water in filled systems can cause gross inaccuracies.
|
Top
|
 |
|
|
Copyright © 2001-2008 Tel-Tru Manufacturing